top of page
UTS1004 EUI & EUP TESTER

UTS1004 EUI & EUP TESTER

Stok kodu: UTS1004

UTS1004 is the all makes Unit Injector and Unit Pump Test Bench. Currently more than 1000 units actively being used in 75 different countries, prooving its wide range capability and effectiveness.

 

Features

Adjustable Cam Stroke 

provides testing being as close to as standard working conditions of the injector. Internal pressure level maintains same as when running on the engine, creating a similar condition like in the engine and allowing the delivery to be compatible to the engine conditions. 

 

UTS1004 patented Cam Box design, allows to set the cam stroke without 

  • draining oil,
  • removing cam
  • adjusting timing

It only takes turning a knob a few times to set the cam stroke. 

 

Wide Application Range; from Caterpillar to Continental VDO

UTS1004 has the technical infrastructure to test 

  • Caterpillar EUI: 3406E; C15; C10;C11;C12;C13;C18; 3116 MEUI, 3500 MEUI; 3500E.
  • Cummins: Celect N14/M11/M11+; HPI (ISX and QSK); K-STC;
  • Bosch EUI/EUP all types.
  • Delphi: A0; A3; E1; E3; F2P
  • Detroit Diesel: all types.
  • Continental VDO all types.

 

SRT Measurement

UTS1004 is capable to measure the Solenoid Response Time. SRT value determines the condition of the solenoid, assembly of the control valve with the spring tension and valve stoke. SRT value determines the timing of the delivery and thus relates to many problems such as smoke at accelleration and idling problems.

 

Easy User Interface with Test Plan Create and Calibrate Function

UTS1004 user interface provides all the necessary data on the test screen readily availible for the user to decide the condition of the injector. The software allows the use to create different test plans. Software help user to keep the test plan target values calibrated with its automatic calibration feature. 

Dimensions 

 

Machine Dimensions:

Width: 1200 mm

Depth: 800 mm

Height: 1830 mm

Weight: 590 kg

 

Packing Dimensions:

Width: 1390 mm

Depth: 1080 mm

Height: 1970 mm

Weight: 700 kg

 

Utilities 

 

Electricity Requirement

360-415 Vac 3 phase 50/60 Hz.

Transformer must be used when local supply is 200-240 3 phase 60 hz.

 

100- 240 Vac 1 phase 50/60 Hz for electronics and computer.

 

Air Supply

Min 5 bar, oil and water free @6L/min flow.

 

 

Technical Specifications 

 

Mechanical Equipment

Main Motor  7.5 kW
Speed Control AC Drive: 100 to 1200 rpm
Cam Box Universal Profile, stroke set between 10 and 18 mm.

 

Test Oil Transfer System

Tank 30 L
Pump 4 L/min; gear type
Supply Pressure 0-25 bar; manually adjusted
Return Pressure 0-6 bar; manually adjusted
Test Oil Heater 2kW
Test Oil Cooler

Air Cooled, with -5 °C/min with 4L/min transfer; usin

a seperate transfer pump

 

Instrumentation

Flow/Delivery

Gear Type Flowmeter; max capacity 1000 mm3/str

digitally displayed as graph mm3/str vs time

SRT

±10µs accuracy with respect to real BIP,

digitally displayed as graph SRT Value (µs) vs test time

Inlet Pressure 0-25 bar, digitally displayed

Return

Pressure

0-6 bar, digitally displayed

Supply

Temperature

10-160 °C digitally displayed

Return

Temperature

10-160 °C digitally displayed
bottom of page