UTS1004 EUI & EUP TESTER
UTS1004 is the all makes Unit Injector and Unit Pump Test Bench. Currently more than 1000 units actively being used in 75 different countries, prooving its wide range capability and effectiveness.
Features
Adjustable Cam Stroke
provides testing being as close to as standard working conditions of the injector. Internal pressure level maintains same as when running on the engine, creating a similar condition like in the engine and allowing the delivery to be compatible to the engine conditions.
UTS1004 patented Cam Box design, allows to set the cam stroke without
- draining oil,
- removing cam
- adjusting timing
It only takes turning a knob a few times to set the cam stroke.
Wide Application Range; from Caterpillar to Continental VDO
UTS1004 has the technical infrastructure to test
- Caterpillar EUI: 3406E; C15; C10;C11;C12;C13;C18; 3116 MEUI, 3500 MEUI; 3500E.
- Cummins: Celect N14/M11/M11+; HPI (ISX and QSK); K-STC;
- Bosch EUI/EUP all types.
- Delphi: A0; A3; E1; E3; F2P
- Detroit Diesel: all types.
- Continental VDO all types.
SRT Measurement
UTS1004 is capable to measure the Solenoid Response Time. SRT value determines the condition of the solenoid, assembly of the control valve with the spring tension and valve stoke. SRT value determines the timing of the delivery and thus relates to many problems such as smoke at accelleration and idling problems.
Easy User Interface with Test Plan Create and Calibrate Function
UTS1004 user interface provides all the necessary data on the test screen readily availible for the user to decide the condition of the injector. The software allows the use to create different test plans. Software help user to keep the test plan target values calibrated with its automatic calibration feature.
PRODUCT INFO
Dimensions
Machine Dimensions:
Width: 1200 mm
Depth: 800 mm
Height: 1830 mm
Weight: 590 kg
Packing Dimensions:
Width: 1390 mm
Depth: 1080 mm
Height: 1970 mm
Weight: 700 kg
Utilities
Electricity Requirement
360-415 Vac 3 phase 50/60 Hz.
Transformer must be used when local supply is 200-240 3 phase 60 hz.
100- 240 Vac 1 phase 50/60 Hz for electronics and computer.
Air Supply
Min 5 bar, oil and water free @6L/min flow.
Technical Specifications
Mechanical Equipment
Main Motor | 7.5 kW |
---|---|
Speed Control | AC Drive: 100 to 1200 rpm |
Cam Box | Universal Profile, stroke set between 10 and 18 mm. |
Test Oil Transfer System
Tank | 30 L |
---|---|
Pump | 4 L/min; gear type |
Supply Pressure | 0-25 bar; manually adjusted |
Return Pressure | 0-6 bar; manually adjusted |
Test Oil Heater | 2kW |
Test Oil Cooler |
Air Cooled, with -5 °C/min with 4L/min transfer; usin a seperate transfer pump |
Instrumentation
Flow/Delivery |
Gear Type Flowmeter; max capacity 1000 mm3/str digitally displayed as graph mm3/str vs time |
---|---|
SRT |
±10µs accuracy with respect to real BIP, digitally displayed as graph SRT Value (µs) vs test time |
Inlet Pressure | 0-25 bar, digitally displayed |
Return Pressure |
0-6 bar, digitally displayed |
Supply Temperature |
10-160 °C digitally displayed |
Return Temperature |
10-160 °C digitally displayed |